Venus Versa™

Vs.

Multi-Treatment Platform.

A versatile multi-application platform that provides the most popular, non-invasive aesthetic procedures, including photorejuvenation/photofacial, acne treatment, hair removal, skin resurfacing, body contouring, cellulite reduction, skin tightening, and wrinkle reduction.

Venus Versa™ Device

TriBella™

TriBella™ is a complete skin rejuvenation treatment, which combines three effective, unique technologies into one treatment protocol to improve tone, tightness, and texture. Exclusively available with our Venus Versa™ system, TriBella™ treatments give clients a more youthful appearance.

Target Tone, Texture, & Tightness

Skin Resurfacing with NanoFractional Radio Frequency

The Venus Viva™ MD applicator is is a highly customizable skin resurfacing technology with low downtime and is safe for all Fitzpatrick skin types.

  • MORE
    • NanoFractional skin resurfacing allows the operator to customize ablation and coagulation settings. Radio frequency energy is delivered into the skin, creating micro-channels surrounded by intact tissue, which promote faster wound healing, little-to-no downtime, and reduces the risk of post-inflammatory hyperpigmentation (PIH).
    • SmartScan™ technology uses a unique algorithm and pattern selection technology that enables the operator to generate customized patterns for maximum flexibility and patient safety.
    • Improves the appearance of textural skin conditions such as scars (including acne scars), rosacea, striae, uneven skin texture, enlarged pores, dyschromia, and pigmentation.

Intense Pulsed Light (IPL) Technology with SmartPulse™

The IPL photorejuvenation, acne treatment, and hair removal applicators include innovative SmartPulse™ technology to ensure comfortable, precise, and consistent energy delivery through advanced pulse optimization. Real-time cooling system monitors the light-guide temperature 1,000 times a second for unparalleled patient safety and comfort.

  • MORE
    • Photorejuvenation/Photofacial: Effectively target & treat vascular and pigmented lesions on the skin.
    • Hair Removal: Efficiently target melanin in the hair shaft for comfortable hair removal treatments.
    • Dual-light-guide Acne Treatment: Innovative dual-light-guide technology: blue light targets porphyrin caused by Propionibacterium Acnes bacteria, leading to the destruction of the P. Acnes bacteria, while the red light promotes faster healing and effectively decreases inflammation.

Multi-Polar Radio Frequency

Body contouring, cellulite reduction, skin tightening, and wrinkle reduction:

Unique combination of Multi-Polar Radio Frequency (RF) and Pulsed Electro Magnetic Fields (PEMF).

  • MORE
    • With the capabilities of multi-polar radio frequency applicators, the Venus Versa™ uses a complex algorithm to deliver homogeneous energy and volumetric heating to multiple tissue depths, allowing for quick and safe buildup of heat and easy maintenance of therapeutic temperature throughout the treatment
    • Effect of Multi-Polar RF is enhanced by PEMF, a non-thermal mechanism emitted through the applicator’s electrodes
    • Through synergistic (MP)², RF heats and directly stimulates fibroblasts, while PEMF is known to promote angiogenesis and induce fibroblast proliferation through release of the growth factor FGF-2, resulting in increased collagen synthesis²
    • (MP)² is therefore effective in collagen remodeling for body contouring via skin tightening, cellulite reduction, and wrinkle reduction, and the creation of new capillaries for renewal of blood supply.

Venus Versa™ offers three unique technologies: Intense Pulsed Light (IPL) with SmartPulse™, NanoFractional Radio Frequency with SmartScan™, and Venus proprietary (MP) 2 technology (Multi-Polar Radio Frequency + Pulsed Electro Magnetic Fields).


With the ability to meet today’s most in demand aesthetic treatments the Venus Versa™ is a sound investment for any clinic looking to expand its offerings with one workstation. Our versatile multifunction machine allows you to offer a variety of services, increase patient demand and positively impact your ROI – all factors that will help your practice thrive for years to come.

TECHNOLOGY

Photorejuvenation

Photorejuvenation treatment

The photorejuvenation protocol in the TriBella™ treatment corrects benign pigmented lesions and benign vascular lesions.

Wrinkle Reduction

Enhances collagen production to reduce the appearance of skin laxity, wrinkles and rhytides.

Wrinkle Reduction treatment

Skin Resurfacing

Skin Resurfacing treatment

Improves the appearance of textural skin conditions such as scars (including acne scars), rosacea, striae, uneven skin texture, enlarged pores, dyschromia, and pigmentation.

The Results Speak for Themselves

All of the before-and-after photos for our aesthetic treatments are from certified Venus providers showcasing real patient results. Images are never edited or altered.

Tech Specs

Technology
  • AC DUAL IPL APPLICATOR

    Wavelength - 415-480 nm, 630-950 nm


    Optical Fluence - 5-25 J/cm2


    Pulse Duration - 10-20 ms


    Spot Size - 10 mm x 30 mm


    Pulse Repetition Rate - Up to 3 Hz

  • NANOFRACTIONAL RF™ APPLICATOR

    Output RF Frequency - 0.46 MHz


    Fuse -3.15A, 250V


    Max. Output Energy - 62 mJ/pin


    Ablation Depth - Up to 500 microns


    Number of Pins - Up to 160

  • DIAMONDPOLAR™ & OCTIPOLAR™ APPLICATORS

    Output RF Frequency - 1MHz


    RF Output Power- 0-150 Watts


    Number of (MP)2 Synthesizers - Up to 8 


    Magnetic Pulse Frequency - 15 Hz


    Pulsed Magnetic Field - Up to 15 Gauss



  • Device

    Electrical Requirements - 100-240 VAC ,12.5A, 50-60Hz, Single Phase


    Dimensions - 55 cm x 65 cm x 110 cm / 21.7 in x 25.6 in x 43.3 in (D x W x H)


    Weight - 35 Kg / 77.2 lb

  • SR515 / SR580 IPL APPLICATORS

    Wavelength - 515-950 nm, 580-950 nm


    Optical Fluence - 5-25 J/cm2


    Pulse Duration - 10-20 ms


    Spot Size - 10 mm x 30 mm


    Pulse Repetition Rate - Up to 3 Hz

  • HR650 (XL) / HR690 (XL) IPL APPLICATORS

    Wavelength - 650-950 nm, 690-950 nm 


    Optical Fluence - 5-20 J/cm2


    Pulse Duration - 20-50 ms 


    Spot Size - 10 mm x 30 mm (XL: 20 mm x 30 mm)


    Pulse Repetition Rate - Up to 3 Hz

Venus Versa Device
  • “The Venus Versa™ platform technology provides the best combination of all. With about 10 different handpieces, each for different procedures, I, as the physician, can choose which combination is best suited to my practice, my patients. I selected Venus Versa™ with Intense Pulsed Light for hair removal and skin rejuvenation.”

    Robert M. Freund, MD

Speak To An Expert

To book a consultation or a demo, please contact us by clicking the button below and a representative will reach out to you directly.

INDICATIONS

Venus Versa™ and Venus Versa™ Pro indications: *Venus Versa™ est homologué par Santé Canada comme appareil multiapplications destiné à être utilisé dans le cadre de traitements cosmétiques et esthétiques. Les applicateurs SR515 et SR580 sont homologués par Santé Canada pour le traitement des lésions épidermiques et cutanées pigmentées bénignes et le traitement des lésions vasculaires cutanées bénignes. Les applicateurs HR650/HR650XL et HR690/HR690XL sont homologués par Santé Canada pour l’élimination des poils indésirables et pour la réduction permanente des poils, ou une réduction des poils dont les effets sont stables à long terme, pour les types de peau Fitzpatrick I à IV. Les applicateurs à double courant alternatif sont homologués par Santé Canada pour le traitement de l’acne vulgaris. L’applicateur DiamondPolar™ est homologué par Santé Canada pour le traitement non invasif des rides modérées à profondes et des plis faciaux chez les femmes présentant un type de peau Fitzpatrick I -IV. L’applicateur OctiPolar™ du système Venus Versa™ est homologué par Santé Canada pour le remodelage corporel temporaire obtenu par le raffermissement de la peau, la réduction circonférentielle et la réduction de la cellulite. L’applicateur de RF NanoFractional™ (Viva) est homologué par Santé Canada pour les traitements dermatologiques nécessitant une ablation ou un resurfaçage de la peau..


REFERENCES:


Ponqgsrihadulchai N, Chalermchai T, Ophaswongse S, Pongsawat S, Udompataikul M. An efficacy and safety of nanofractional radiofrequency for the treatment of striae alba. J Cosmet Dermatol. 2016; 1-7.↩

Callaghan, M. J., Chang, E. I., Seiser, N., Aarabi, S., Ghali, S., Kinnucan, E. R., . . . Gurtner, G. C. (2008). Pulsed Electromagnetic Fields Accelerate Normal and Diabetic Wound Healing by Increasing Endog

Share by: